KODEX Explorer v2.1Live LabPre-FEM screening

Candidate rotor/stator configuration lab

Compare exploratory axial generator geometries with clear separation between model observations, hypotheses, and validation work still required.

Selected
20M / 12C
RTI
9.35
Model Consistency
High
Observations
exploratory model outputs
Interpretations
hypotheses only
Validation
FEM and prototype pending

Scientific integrity note: Explorer v2.1 is a pre-FEM exploratory screening tool. RTI and related scores are unitless ranking indicators. They are not real torque, not N·m, not efficiency, and not proof of energy gain.

Configuration

Candidate inputs

Number of magnets
Number of coils
Magnet size
Phase system

Controls update the L1 exploratory screening calculations only. FEM-linked controls are planned for a later module.

Rotor / stator

Angular alignment view

Promising candidate
20M / 12C is the current investigation candidate, not the final architecture. Promising in exploratory ranking only — not physically validated.
NSNSNSNSNSNSNSNSNSNSABCABCABCABC20 magnets12 coils / 3-phasepole pitch 18.0°
Magnet coverage15.3°
Coil pitch30.0°
Interaction density0.67

Interpretation

Research notes

What we observe

The 20-magnet candidate produces an RTI of 9.35 with 96.2% coverage score and 84.4% phase alignment in this exploratory model.

Why it may matter

20 magnets appears promising in the current exploratory model, but the reason is not yet proven. It may be related to angular coverage, pole spacing, interaction with 12 coils / 3 phases, or bias in the scoring model. FEM simulation is required before drawing engineering conclusions.

What is still unknown

The model does not resolve flux leakage, saturation, winding geometry, thermal behavior, cogging detail, manufacturing tolerance, or measured electrical output.

What must be validated with FEM/prototype

Run FEM field solutions, compare candidate geometries under the same material assumptions, then measure a prototype before treating any ranking as an engineering result.

Metrics

Exploratory values

Magnet count20
Coil count12
Pole pitch angle18.00°
Coil pitch angle30.00°
Magnet angular coverage estimate15.32°
Magnet-to-coil interaction density0.667
Relative Torque Index (RTI)9.35
Phase alignment score84.4%
Coverage score96.2%
Symmetry / balance score96.8%
Model ConsistencyHigh
Phase system3-phase
This is an internal model-consistency indicator, not a physical validation confidence score. FEM simulation and prototype testing are still required.

Relative Torque Index (RTI)

The Relative Torque Index is an exploratory, unitless ranking score. It is not real torque, not N·m, not measured efficiency, and does not validate energy gain. It is only used to compare candidate configurations before FEM and prototype validation.

Validation boundary

Results here are candidate-screening signals. Engineering conclusions require FEM simulation, prototype measurement, and review against the physical build path.

Candidate data

Exploratory model only. Requires FEM and prototype validation. RTI is a unitless ranking score and is not real torque, not N·m, and not measured efficiency.

Sweep

RTI vs magnet count

Sweep

Phase alignment vs magnet count

Sweep

Coverage score vs magnet count

Comparison

Candidate table

Status is a research triage label from the exploratory model, not a validation result.

MagnetsCoilsPole pitchCoverage scorePhase alignmentRTIStatus
81245.0°41.5%19.4%4.73Baseline
121230.0°62.3%53.9%6.60Needs validation
161222.5°83.1%72.8%8.24Interesting
201218.0°96.2%84.4%9.35Promising
Exploratory only
241215.0°75.4%72.0%7.89Interesting
321211.3°33.9%67.0%5.72Needs validation